CAN Bus Displays (CAN Bus Digital Clusters)

We are Manufacturer, Supplier, Exporter of CAN Bus Displays (CAN Bus Digital Clusters) from Pune, Maharashtra, India.

CAN Bus Displays / Digital Cluster

INTRODUCTION

Twintech design and manufacture CAN Bus Displays for all type of vehicles

CAN Bus Displays refer to displays that are integrated into a Controller Area Network (CAN) bus system. The CAN bus is a vehicle bus standard designed to allow microcontrollers and devices to communicate with each other without a host computer. It is commonly used in automotive and industrial applications for connecting various electronic control units (ECUs) within a vehicle or machinery.

CAN Bus Displays are often found in vehicles and industrial equipment where real-time data communication between different components is essential. These displays can show information such as vehicle speed, engine RPM, fuel level, temperature, and other relevant data obtained from sensors and control units connected to the CAN bus network.

These displays play a crucial role in providing drivers or operators with essential information about the status and performance of the vehicle or machinery in real-time, enabling them to make informed decisions while operating the equipment.


1). Round CAN Bus 1.28” Display

Key Features :

Round CAN Bus 1.28” Display
Very Compact size
Round Colour full Display
Connectivity Bluetooth
Interactive user Interface for any 2 parameters
Waterproof IP65
Panel Mount
Country of Origin: Make In India

Technical specifications

Supply 9-32 V DC
Input CAN/ 1 Magnetic Pickup
Display Rround TFT Colour Display 1.28 Inch TFT LCD
Resolution 240 X 240 dots (RGB)
Brightness 400 cd/m²
Operating Temperature -20 to +70° C
Hours Range 0 to 99999.09 Hrs
IP 65
Accuracy 0.5%
Cut out Size 52.0 mm Round Diameter
Enclosure Nylon 6
Connector 6 Pin connector MSSL Series




2). Round CAN Bus 2.5" Display

Key Features :

Round CAN Bus 2.5" Display
Export Quality
2.5" TFT LCD Full Colour Display
Connectivity Bluetooth
Rugged and can withstand extreme environments
Interactive user Interface for 2 to 4 Parameters
Waterproof IP65
Panel Mount
Country of Origin: Make In India

Technical specifications

Supply 9-32 V DC
Input CAN/ 4 inputs
Display TFT Colour Display 2.5"TFT LCD
Resolution 320 X (RGB) X 240
Brightness 400 cd/m²
Operating Temperature -20 to +75° C
IP 65
Accuracy 0.5%
Cut out Size 85.0 mm Round Diameter
Enclosure Nylon 6
Connector Deutsch Connectors




3). CAN Bus Displays 4.5"

Key Features :

CAN Bus Displays 4.5
4.5" TFT LCD Full Colour Display
Square Shape
Agricultural application
Interactive user Interface for 2 to 4 Parameters
Waterproof IP65
Panel Mount
Country of Origin: Make In India

Technical specifications

Supply 9-32 V DC
Input CAN/ 4 inputs
Display TFT Colour Display 4.5"TFT LCD
Resolution 480X854
Brightness 300 cd/m²
Operating Temperature -20 to +70° C
IP 65
Accuracy 0.5%
Cut out Size Nylon 6
Enclosure TE Connector Automotive Connector
Connector Panel / Surface




4). CAN Bus Displays 7.0

Key Features :

CAN Bus Displays 7.0
7.0" TFT LCD Full Colour Display
Square Shape
Agricultural and Construction application
Interactive user Interface for 4 to 6 Parameters
Waterproof IP65
Panel Mount
Country of Origin: Make In India

Technical specifications

Supply 9-32 V DC
Input CAN/ 7 inputs
Display TFT Colour Display 7.0"TFT LCD
Resolution 1024X600
Brightness 460 cd/m²
Operating Temperature -20 to +70° C
IP 65
Accuracy 0.5%
Cut out Size Nylon 6
Enclosure TE Connector Automotive Connector
Connector Panel / Surface





Application

CAN Bus Displays and digital cluster is very useful in diesel generators for various applications: Monitoring Engine Parameters: CAN Bus Displays can be used to monitor critical engine parameters such as oil pressure, coolant temperature, fuel level, exhaust temperature, and battery voltage. This real-time monitoring helps in ensuring the engine operates within safe limits. Fault Diagnostics: CAN Bus Displays can provide diagnostic information in case of faults or abnormalities in the generator system.  Remote Monitoring and Control: With the help of CAN Bus Displays, operators can remotely monitor the status of the diesel generator, including its operating parameters and performance. They can also remotely control certain functions such as starting/stopping the generator, adjusting load, and changing operating modes. Fuel Management: CAN Bus Displays can provide accurate information about fuel consumption and remaining fuel levels in the generator's tank. This helps in efficient fuel management and scheduling refueling operations. Maintenance Scheduling: By monitoring various parameters and performance indicators, CAN Bus Displays can assist in predictive maintenance scheduling. This ensures that maintenance activities are performed proactively, minimizing downtime and reducing the risk of unexpected failures. Integration with Overall System: CAN Bus Displays can be integrated into the overall control and monitoring system of a diesel generator. This allows seamless communication between different components of the generator system and enables centralized monitoring and control. Data Logging and Analysis: CAN Bus Displays can log data related to generator operation and performance over time. This data can be analyzed to identify trends, optimize performance, and improve overall efficiency of the generator system.

Responsive Image

Marine

In marine applications, CAN Bus Displays are used on boats and ships for monitoring engine performance, fuel levels, navigation information, and other essential systems on board. They are crucial for ensuring the safe and efficient operation of marine vessels.

Responsive Image

Agricultural Machinery

CAN Bus Displays are commonly found in agricultural machinery such as tractors and harvesters. They provide farmers with real-time information about crop health, equipment status, GPS guidance, and other data necessary for efficient farm operations.

Responsive Image

Heavy Equipment

Construction and mining equipment often use CAN Bus Displays for monitoring engine performance, hydraulic systems, fuel consumption, and other vital parameters. These displays help operators optimize equipment usage and prevent costly downtime.